A Hormann retractable double door chassis ready to be clad on site. The 2011 lets one wide door carry the same boarding as the building around it, with the mechanism engineered for you.
Made 11ft to 14ft wide at 6ft 6in or 7ft high. Brown or white chassis, a 75mm steel frame and a ProMatic or SupraMatic operator are all available.
- German Manufactured High Quality Doors
- 11 - 14ft wide double doors
- Create your own design
- Retractable Mechanism
- Related Downloads
- Hormann Retractable Installation Instructions
- Hormann Canopy Installation Instructions
- Hormann Series 2000 Garage Doors
- Safe Operating and Maintenance of Hormann Garage Doors
- Hormann Promatic Series 4 Operator Installation Instructions
- Hormann Supramatic Series 4 Operator Installation Instructions
- Hormann Promatic & Supramatic Operators (Series 4)
- Hormann Promatic 3 Spec
- Hormann and Garador Open for Infill Up and Over Installation instructions
Hormann 2011 Open for Infill Double Door
A wide garage with a timber or clad front deserves a door that looks like part of the building. The double 2011 gives you a Hormann retractable up and over door ready to be faced on site, so one large door can carry the same boarding as the walls, gables or gates around it.
What Hormann supplies
The door leaf chassis comes fully welded, with reinforcing struts across its width and holes drilled every 30mm for fixing battens or boards from behind. The retractable gear and springs are set up for an infilled leaf, so once the cladding is on the door balances and runs as Hormann intends.
Choosing the infill
Keep the finished infill between 6 and 10kg per square metre. Lightweight softwood boards, shiplap or a composite panel usually sit comfortably in that range. Boards that overlap the frame can be up to 16mm thick, and the leaf is 58mm narrower and 10mm lower than the ordering reference.
Double widths
• Widths from 3353mm, 11ft, up to 4267mm, 14ft
• 6ft 6in or 7ft high, 1981mm or 2134mm
• Retractable gear on every size
Automation
Both Hormann ProMatic and SupraMatic operators can be added, so a heavy looking timber faced double can still open from the car at the press of a button.
Choosing your width and height
The sizes in the menus are Hormann ordering references, based on traditional imperial garage door sizes. They are close to the size of the door and the frame opening, but they are not an exact measurement of either. The figures to work from are the overall frame sizes in millimetres, listed for every size in the Installation tab. With the 75mm steel frame, the overall frame is 140mm wider and 57mm taller than the ordering reference. Compare those overall frame sizes with your opening, and use the Measure tab for a step by step guide.
The double 2011 is made 11ft, 12ft, 13ft or 14ft wide, each at 6ft 6in or 7ft high. All double sizes use retractable gear.
Retractable gear
Double doors slide back into the garage on horizontal tracks, so nothing projects over the drive when the door is open.

Chassis colour
Choose a Brown or White chassis. Hormann primes the galvanised leaf frame in Terra Brown RAL 8028 or Traffic White RAL 9016. Pick the colour closest to your infill, as small gaps and the inside of the door will show it.
Before you choose your infill
• Finished infill weight between 6 and 10kg per square metre
• Boards that overlap the frame can be up to 16mm thick, plus a 1mm gap
• The standard lock cylinder suits infill up to 19mm thick set within the frame. Thicker infill needs a longer cylinder at extra cost
Steel fixing frame
Double doors use the 75mm steel frame, offered in white or brown to suit the chassis colour. You can also fit the door to an existing timber frame if it is sound, square and at least 70 x 70mm.
Electric operator
Choose the ProMatic for everyday domestic use or the SupraMatic for faster running and more accessories. Both use BiSecur encrypted radio, include 2 hand transmitters and have a courtesy light. Check the height limit shown against each operator in the menu.
Hormann also makes a de latch kit that links the door latches to the operator. Ask us if you would like one added.
Emergency external release
If the garage has no other way in, add the external release so the door can be opened from outside during a power cut.
Infill designs
• Infill overlapping the frame, concealing the leaf frame and bottom section
• Infill within the frame, with the bottom section left visible as a splash guard
Infill limits
• Minimum infill weight 6kg per square metre
• Maximum infill weight 10kg per square metre
• Maximum thickness for infill overlapping the frame 16mm plus a 1mm gap, 17mm in total
• Door leaf size: ordering width less 58mm by ordering height less 10mm
• Lock cylinder suits infill up to 19mm thick within the frame, longer cylinder available for thicker infill
• Hormann layout guides for vertical or chevron boarding are included in the infill instructions
Chassis
• Fully welded leaf frame with reinforcing struts
• Fully galvanised, with a polyester primer coat in Terra Brown RAL 8028 or Traffic White RAL 9016
• Frame and struts pre drilled at 30mm spacings for fixing the infill
• Lateral uPVC weather seal fitted to the lower part of the frame and the top of the door, acting as a trap guard and sound absorber
Sizes
• 3353mm, 3658mm, 3962mm and 4267mm wide
• 1981mm or 2134mm high
• 8 ordering references, all retractable
Operating gear
• Retractable gear on all double sizes
• Multiple spring safety system with tightly coiled springs
• Spring and cable break safety conforming to BS EN 12604
• uPVC rollers and bushes in the door bearings, with a buffer stop
Locking
• Round black handle outside with a rotary disc inside
• Profile half cylinder lock with a release button on the inside
• 2 point locking by adjustable automatic uPVC latches
Frame
• Optional 75mm steel box section frame in white or brown
• Overall frame size is the ordering reference plus 140mm on the width and 57mm on the height
• Can also be fitted to a 70 x 70mm timber frame
Electric operation
• Hormann ProMatic or SupraMatic operator with BiSecur radio and 2 hand transmitters
• Soft start and soft stop, safety cut out, automatic locking and internal manual release
• Emergency external release available
Also available
• Matching 2011 open for infill side doors, 875mm or 1000mm wide
What arrives with your door
The double 2011 chassis is delivered with its retractable gear fitted and full instructions. Steel brackets and screws come with the steel fixing frame, or timber screws for a timber frame installation. You provide the fixings into the masonry and the infill materials.
A double leaf up to 14ft wide needs at least 2 people to handle, and more once it is clad. Many installers fit the frame and leaf first and add the boards with the door in place, keeping the leaf secured against opening until the infill is complete.
Fitting instructions to download
Hormann open for infill boarding guide
Hormann retractable gear fitting instructions
Where the door can be fitted
A Hormann up and over door with a steel frame can go between the piers of the opening or onto the inside face of the wall behind it, but not on the front face. Fitting behind the opening allows a wider and taller door than fitting between the same piers, which can make a real difference to the clear drive through space. The choice usually comes down to the depth and condition of the piers and how you want the finished door to look. If you are unsure which suits your garage, call or email us before ordering.
Ordering references, overall frame sizes and brick openings
The recommended brick opening is the Hormann figure for fitting a double door with the 75mm steel frame between the piers, and it already includes the fitting allowance.
| Ordering reference mm | Imperial reference | Overall frame mm with 75mm steel frame | Recommended brick opening mm for fitting between the piers |
|---|---|---|---|
| 3353 x 1981 | 11ft 0in x 6ft 6in | 3493 x 2038 | 3504 x 2044 |
| 3353 x 2134 | 11ft 0in x 7ft 0in | 3493 x 2191 | 3504 x 2199 |
| 3658 x 1981 | 12ft 0in x 6ft 6in | 3798 x 2038 | 3809 x 2044 |
| 3658 x 2134 | 12ft 0in x 7ft 0in | 3798 x 2191 | 3809 x 2199 |
| 3962 x 1981 | 13ft 0in x 6ft 6in | 4102 x 2038 | 4114 x 2044 |
| 3962 x 2134 | 13ft 0in x 7ft 0in | 4102 x 2191 | 4114 x 2199 |
| 4267 x 1981 | 14ft 0in x 6ft 6in | 4407 x 2038 | 4419 x 2044 |
| 4267 x 2134 | 14ft 0in x 7ft 0in | 4407 x 2191 | 4419 x 2199 |
Warranty
Hörmann products are manufactured to the highest quality standards and leave our factory only after rigorous quality testing. However, if you should have grounds for complaint, this section tells you what our door warranty offers, and how to go about making your claim.
In the unlikely event of a warranty claim becoming necessary, please contact the dealer or distributor who originally supplied your garage door. Your dealer should then supply details of the claim, together with a copy of the warranty card provided with the door and proof of purchase to the Product Services Department at Hörmann (UK) Ltd. To enable your claim under warranty to be processed as quickly as possible, you should provide the following details:
1 Your name, address and telephone number
2 Original invoice with date of purchase
3 Product description/door type and product number
4 Description of defect
An assessment of the claim will then be made. This may require Hörmann to inspect the product in-situ. In the event that there is no legitimate warranty claim under the terms specified herein, you may be liable for the costs of the inspection visit. We strongly recommend that you take note of the care and usage instructions displayed on the stickers on the back of your garage door, and on the page opposite, and that you follow these instructions throughout.
Hörmann (UK) Ltd Garage Door Warranty
Warranty Period The purchaser is granted a warranty covering the safe and reliable function of the Hörmann garage door for a period of 10 years from the date of purchase. A 5 year warranty applies to springs, wire cables, track rollers, hinges and guide rollers. The warranty period for replacement parts is 6 months or to the end of the current warranty period, whichever is longer. In the case of foilcoated timber-effect, a warranty of 5 years is granted, for timber and GRP doors a warranty of 2 years is granted on the door panels alone under the terms and conditions specified herein. The door mechanism and steel frame (if applicable) is covered by the 10 year warranty period.
Requirements
Warranty claims are only applicable in the country where the garage door was purchased. The product must have been purchased through our authorised distribution channels. The warranty only covers damage to the contract object. The fully completed warranty card together with the receipt of purchase correspondingly dated substantiates your right to claim under the warranty.
Performance
During the warranty period we undertake to rectify any and all defects to the Hörmann product which can be proved to be attributed to a material or manufacturing fault. We pledge at our discretion either to exchange the defective merchandise for faultless merchandise, repair it or allow a reduction in price. We do not accept costs for dismantling and installation nor for carriage.
Replaced parts become our property.
The warranty does not cover damage caused through:
• normal wear and tear
• improper installation
• negligent care and maintenance
• improper initial and subsequent operation
• negligent or wanton destruction
• external influences such as fire, water, salts, alkaline solutions, acids, abnormal environmental influences
• mechanical damage through improper transport and fitting
• priming and other surface protection treatments
• incorrect or too late applied surface protection treatments
• repair by non-qualified persons
• using non-Hörmann parts without the approval of the manufacturer
• removal of the product number or making it unidentifiable
Electric Operator Warranty
A separate 5 year warranty is granted on our electric operators. This includes operator mechanics, motor and motor control systems. A 2 year warranty is granted on radio equipment, accessories and system controls. There is no warranty on consumables (e.g. fuses, batteries, bulbs etc.).
User Information/Care
Finish - Steel Doors
The coating process applied to the door and chassis is environmentally friendly. Minor scratches or marks are not covered under the conditions of our warranty and should be repaired immediately to prevent corrosion and deterioration of the panel. Corrosive substances such as acids, alkalines, and salts, etc. should be cleaned from the door immediately; failure to do so will result in deterioration of the finish, which will not be covered under our warranty. Should deterioration of the finish start to occur you will need to repaint your door immediately. Prepare the surface lightly with wet and dry. Then treat with solvent based 2 pack epoxy wash primer and a normal commercial paint (cellulose paint must not be used). Hörmann steel doors are a finished product. They do not require re-painting on site. They are however not immune to damage, which can occur at any stage of the handling of the product from factory to site.
Finish - Timber Doors
Timber panels are coated with a neutralising base-stain. Doors must be stored upright, under cover, with wrapping intact, until wrapping is removed. As soon as the door is unwrapped, one coat of a good quality basecoat primer must be applied to both sides of the door. Immediately after installation, your timber doors require a further two coats of a good quality exterior wood finish on both sides. Initial application and periodic treatment should be carried out strictly in accordance with the woodstain manufacturer's instructions. Failure to follow these instructions will result in early deterioration of the timber panel.
Finish - GRP Doors
GRP door panels should periodically washed down using water. This should be done more frequently if fitted near the sea. Bird droppings will bleach the finish on GRP. and should be removed using water as soon as possible. GRP doors should not be painted over.
Paint Finish - Steel Doors
Minor surface damage can easily be repaired using touch up sprays or sticks without invalidating warranties.
Safe Operating and Maintenance of Hormann Garage Doors PDF >
Start with where the door will go
Before measuring, decide whether the new 2011 Open for Infill double door will fit between the piers of your opening, behind the opening on the inside wall, or into an existing timber frame. Each route uses a different measurement, so decide first.

Fitting between the piers with a steel frame
• Measure the brick opening width at the top, middle and bottom, and note the smallest figure
• Measure the height at the left, centre and right, from the finished floor level to the underside of the lintel, and note the smallest figure. Series 2000 doors have no bottom threshold rail, so the door closes onto the floor itself
• Allow about 10mm on the width and 5mm on the height for fitting
• Choose the largest ordering reference whose overall frame size in the Installation tab fits within those figures
The Installation tab also lists the brick opening Hormann recommends for each double size, which already includes this allowance.
Fitting into an existing timber frame
Check the frame is sound, square and firmly fixed along its full width, as a long frame head can sag over time. Measure between the frame legs and from the floor to the underside of the head, choose the ordering reference closest to those internal sizes, and check the fit with us if it is tight. Hormann designs these doors to fit a 70 x 70mm timber frame.
Fitting behind the opening
Choose an ordering reference whose overall frame size is larger than the brick opening, so the frame sits on the wall face behind the piers and lintel. Double doors need more room than singles. Hormann asks for at least 110mm of solid wall on one side of the opening and 87mm on the other, so allowing 110mm on both sides is the safe approach. The inside of the garage needs to be at least 20mm wider than the overall frame, with at least 90mm of headroom above the frame, rising to 105mm with a SupraMatic operator.
A worked example
A double opening measures 4420mm wide and 2200mm high at its smallest points. Taking off the fitting allowance leaves 4410mm by 2195mm. The 4267 x 2134 ordering reference with the 75mm steel frame has an overall frame size of 4407 x 2191mm, so it fits between the piers.
Before you order
Plan the infill before ordering, as a heavy board on a 14ft leaf can quickly exceed 10kg per square metre. If your sizes fall between two ordering references, or the opening is out of square, send us your measurements and a photo and we will help you choose.