Up and Over Garage Doors

Payment logos
Shopping cart £0.00 0 item(s)
GO TO BASKET »
 
Measuring for Up and Over Doors
How To Measure and order up and over garage doors

Measuring Up and Over Garage Doors

When measuring any garage aperture it is important to start by measuring the width and the height in several places from the top to bottom and left to right. This is to find the smallest dimensions which become the measurements you work with when installing INBETWEEN this opening. If you are installing BEHIND the opening (face fitting inside) then you do have more flexibility in sizing and ordering generally, as long as the garage door panel size is smaller than the aperture size it will be able to operate.

Up and Over garage doors are always ordered by their internal fixing sub frame dimensions in the U.K. - in other words, the internal width and height of the sub frame opening, which is usually either a timber or steel box section. The exceptions are the purpose made doors where both measurements are best provided when ordering with a fixing sub frame. Tell us the overall width and height required with the frame and the opening size inside the sub frame, this way we know it has been properly understood by all.

There are different ways to measure your Up and Over Garage door, based on where your garage door will be installed and whether you choose up re-use the existing sub-frame.

  1. Measuring using an existing timber sub frame
  2. Measuring for installing IN-BETWEEN (reveal) a garage opening
  3. Measuring for installing INSIDE (face-fit) a garage opening
  4. Ordering your Garage Door
  5. Additional information

Canopy Up and Over Garage Doors

Inside View Of Canopy up and over Garage Door Outside View Of A Canopy one piece Garage Door


Retractable Up and Over Garage Doors

Shown below; the optional electric operator motor drive and boom located above the horizontal tracks which the door panel slides along.
The highest point will be this electric operator if fitted with the door and generally is another 30mm above the high point of the door panel travel.
Inside View Of Retractable Up and Over garage door Retractable Up And Over door with electric operator mechanism

Important: ALL Up and Over garage doors require a fixing sub frame for installation and this must be taken into consideration when measuring, ordering and installing.

General rule of thumb: The ordering sizes for an up and over door are the fixing sub frame 'daylight opening' sizes (allow for the chosen sub frame sizes in your calculations!) with some exceptions for purpose made doors on certain manufacturers. For purpose made doors from any manufacturer it is always best to provide both sets of dimensions to be sure - Overall Width and Height including the chosen sub frame and the Ordering Width and Height.


Measuring using an existing timber sub frame

If you are leaving the existing timber sub frame or fitting a new one the same size then the easiest way to get the measurements required to order your new up and over door is to measure the internal frame dimensions only. If the measurements are very close to a standard ordering size then of course you can replace the timber frame and make size adjustments in the sub frame to meet the standard size (as long as the basic sub frame size is 67mm minimum at the sides).

  1. Measure the Width of your existing timber sub frame opening from top to bottom in several places.
  2. Measure the Height of your existing timber sub frame opening from underside of the head frame of the floor in several places

Please also refer to the 'measuring tab' shown in the online shop when placing an order

Take the smallest measurements as the one to use. If there is a large difference in various places then it may be better to remove the frame and replace everything or square the frame up first. A nice square sub frame ensures the best operation for the door mechanism.

Back to the top

Ordering your door


Measuring for installing IN-BETWEEN (reveal fitting) a garage opening

When installing a complete new Up and Over door, operating gear and sub fixing frame in-between a garage opening then all you need to focus on is the width and height in-between the garage opening, as everything will be fitting in-between this opening.

  1. Measure the Width of your structural opening in several places top to bottom.
  2. Measure the Height of your structural opening from top of your opening to the floor in several places.

Take the smallest measurements and use these to calculate the best door and frame size combination, bearing in mind you always need some fitting tolerance. Also note that you don't necessarily have to get an exact fit, the nearest smaller door and frame size is often the best choice. The remaining gaps can then be clad or infill, unless you really want to maximise the opening, in which case look at a purpose made door.

Please also refer to the 'measuring tab' shown in the online shop when placing an order

Back to the top

Ordering your door


Measuring for installing Inside (face-fitting) a garage opening

When installing a new door, mechanism and sub fixing frame inside a garage opening all you have to be aware of is making sure the garage structural opening is wider and higher than your chosen door ordering sizes, but ideally not wider or higher than the overall door and frame dimensions. This gives a lot of flexibility in the potential ordering sizes. Installing to the inside face of a garage also gives you the best drive through dimensions for your garage, maximising the width and height of the garage opening.

  1. Measure the Width of your structural opening in several places
  2. Measure the Height of the structural opening from top of the door opening to the floor in several places
  3. Measure the smallest reveal width on the left side of the structural opening
  4. Measure the smallest reveal width on the right side of the structural opening
  5. Measure the smallest headroom dimension from the top of your garage opening to the lowest obstruction on the ceiling

Please also refer to the 'measuring tab' shown in the online shop when placing an order

Example: A structural garage opening is 2300mm wide and 2200mm high and you want to fit on the inside face of the garage. The best standard size up and over door to order would be a 2286mm wide and 2134mm high (7'6" x 7'0"). The overall width would be about 2426mm by a height of 2192mm for most manufacturers, so in this case a very small infill or quadrant would be required at the head of the frame to fill in the 8mm gap.
All standard up and over doors in the UK are ordered using an imperial reference, which is not always exactly the same size as the metric conversion.

Back to the top

Ordering your door


Ordering your New Up and Over Garage Door

Up and Over garage doors are always ordered by the internal fixing sub frame dimensions in the U.K - in other words, the internal width and height of the sub frame opening which is usually either timber or a steel box section. As different frame sizes are available from different manufacturers and also depending on the size and operating mechanism ordered then working out the overall width and height will depend on your choice of door, manufacturer and mechanism. Check on our 'tabs' in the online shop for the relevant details for each manufacturer.

Purpose made doors are an exception to this, where it is best to provide both measurements when ordering a steel fixing sub frame. 

Tell us the overall width and height required with the frame and the opening size inside the sub frame, this way we know it has been understood before manufacturing.

For pricing purposes the ordering size refers to the dimensions in between the sub frame.

Please also refer to the 'measuring tab' shown in the online shop when placing an order

Back to the top


Additional Information

Download PDF Download PDF Survey Form Visit Our Shop

Back to the top


 

Garage Door Information and Prices